GALIN POWDER COATING MACHINE (ESP101) ELECTRICAL DATA | |
Nominal input voltage | 220V (100V-240VAC) |
Frequency | 50/60 Hz |
Input power | 50 VA |
Rated output voltage | 12~18VPP |
Rated output current | 1.2A |
Protection type | IP54 |
Temperature rang | +10ºC to +40ºC (+50ºF to +104ºF) |
Solenoid Valve Voltage | 24VDC |
Gun output voltage | 0-100KVDC |
Gun output current | 0-100μA |
GALIN POWDER COATING MACHINE (ESP101) PNEUMATICAL DATA | |
MAX.Input pressure | 8bar |
MIN.Input pressure | 5bar |
Output pressure | 0~8bar |
Max.Water vapor content of the compressed air | 1.3g/m³ |
Max.Oil vapor content of the compressed air | 0.1mg/m³ |
Max.Compressed air consumption | 19Nm³/h |
GALIN POWDER COATING MACHINE (ESP101) GUN PARAMETER | |
All the guns in the pictures match the Galin ESP101 | |
Input | 12~18VPP |
Voltage Frequency | Around 25KHZ |
Input Current | 1.2A |
Output Voltage | 0~100KV DC |
Max.Output powder volume | Around 600G/MIN |
Gun cable | 4 M |
Gun weight | 490g |
Error/cause | Troubleshooting |
Injector nozzle, non-return valve unit, powder hose or Powder gun are clogged |
Clean the corresponding parts and if necessary,replace them |
Conveying vacuum too low | Increase the powder quantity and/ or total air volume on the control unit |
Insert sleeve worn , Not or incorrect inserted |
Replace or insert it ,observe the indexing cam |
Insert sleeve is worm after A short operating duration |
Clean the nozzle ,if damaged,replaced it |
The gun does not spray powder although the control unit Is switched on and the Gun trigger is pressed |
1.Connect the equipment to the compressed air 2.Clean /Replace 3.Clean the corresponding 4.Contact Galin representative |